Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Rev. colomb. biotecnol ; 13(2): 70-83, dic 1, 2011. tab, graf
Article in Spanish | LILACS | ID: lil-645169

ABSTRACT

Desde los años sesenta se utilizan las señales electromoigráficas (EMG) como señales de control para prótesis actuadas por servomotores, así como en la estimulación de músculos que sufren de parálisis o de atrofia parcial. Mediante el avance tecnológico se ha logrado mejorar el diseño, así como la fabricación de sistemas protésicos, que funcionan como extensiones de algún miembro del cuerpo humano, agregando además con los nuevos diseños, características básicas como: flexibilidad, estética morfológica, incremento de la relación resistencia/peso así como multifuncionalidad. Una prótesis mioeléctrica es una estructura desarrollada con el fin de reemplazar una parte o la totalidad de un miembro del cuerpo humano, lo mismo que suplir las funciones perdidas de este, sin dejar de lado la imagen corporal del paciente. Estas prótesis son accionadas por actuadores que se controlan a través de señales EMG, las cuales se obtiene mediante agujas intramusculares superficiales o por medio de electrodos colocados en el muñón del paciente. Este tipo de prótesis es cada vez más aceptado por personas con amputación de mano, ya que proporciona un mejor desempeño y permite el incremento de funcionalidad para el paciente que la utiliza, debido a que su control es más sencillo.


Since 60’s electromiographical signals (EMG’s) are used like a control signals for prostheses acted by servomotors, as well as stimulation of muscles that are affected due to partial or total paralysis. By means of technological advance, it has been possible to improve the design as well as the production of prosthetic systems that work as extensions of some member of human body, adding with the new designs also basic characteristics as: flexibility, aesthetic morphology, and superior strength/weight relationship, as well as multi-functionality. Mioelectric prosthesis is a structure developed with the purpose of replacing a part or the entirety member of human body, same as to replace the lost functions of this, without leaving aside patient's corporal image. These prostheses are acted by actuators that are controlled through EMG signals, which are obtained by means of intramuscular or superficial needles, or by means of electrodes placed in patient's stump. This class of prostheses is more and more accepted by people with hand amputation since it provides a better acting, that which allows a superior functionality for patient that uses it, because its control is simpler.


Subject(s)
Prosthesis Design/adverse effects , Prosthesis Design/methods , Prosthesis Design/mortality , Prosthesis Design/standards , Equipment Failure Analysis/statistics & numerical data , Equipment Failure Analysis/instrumentation , Equipment Failure Analysis/methods , Equipment Failure Analysis/standards
SELECTION OF CITATIONS
SEARCH DETAIL